Vertiv Liebert NXL Features
- 6 pulse phase controlled SCR rectifier for 250-400kVA; 12 pulse for 500 – 800kVA
- Input filter with fuses
- Automatic input filter disconnect for input power factor control
- Copper galvanic isolation transformer input and output, 500-750 kVA
- Continuous duty static bypass with internal back feed breaker
- Redundant cooling fans with individual failure detection
- Two step input current limit
- Two step battery charger limit
- Automatic retransfer
- DSP controls
- Back-lit color touch screen display
- Temperature compensated battery charging/battery load test
- Top and bottom cable entry
- Latest UL 1778 Rev. 4 Listing and Labeling
- Safe and easy replacement of air filters and addition of Liebert IntelliSlot® cards without shutting down the unit.
- Internal backfeed breaker
Contact Us about Vertiv Liebert NXL 250-400kVA 208-600V
New Technology For A New Level Of Performance
With over four decades of the most reliable UPS systems, and the industry’s most experienced engineering resources, Vertiv™ has delivered the Liebert® NXL™ UPS—the latest generation of high availability, high performance UPS for critical data center equipment.
- Employs the latest generation insulated gate bipolar transistors (IGBTs) and advanced inverter logic with active harmonic control for enhanced performance under a wide range of power conditions.
- Provides high efficiency, up to 94%, but more importantly, the efficiency is optimized with a very flat efficiency curve that peaks at about 50% load where most UPS systems, especially redundant UPS systems, are operating. This results in significant savings on the energy bill.
- Digital control technology provides precise, drift-free regulation of system operation.
- Supports leading power factor loads up to 0.95 without derating, addressing the power needs of current and future generations of computers.
Higher Availability
- 100% rated continuous duty bypass static switch—unfused.
- Superior handling of present and future leading power factor computer loads.
- Short Circuit Withstand Rating (SCWR) withstand capability: 480V – 65kA, 100kA; 600V – 35kA, 65kA.
- Color touch screen display improve user interface and reduce risk of human error.
- Built-in galvanic isolation provides proper grounding without requiring a neutral.
- Excellent dynamic performance.
- Liebert ActiveStar® Digital Signal Processor (DSP) all digital controls.
- Multi-module configurations provide for greater total capacity and module redundancy.
- Module level redundant components— fans and power supplies.
Contact Us about Vertiv Liebert NXL 250-400kVA 208-600V
Electrical Input:
Power | 250kVA, 300kVA, 400kVA, 500kVA, 625kVA, 750kVA, 800kVA, 1000kVA, 1100kVA |
Nominal Input Voltage | 208v, 220v, 480v, 600v Three Phase |
Input Voltage Range | V -15%, +10% from nominal at 100% load |
Operating Frequency | 50/60Hz |
Input Power Factor | P.F. >.99 typical |
Input Current Distortion | 5% THD |
Electrical Output:
Nominal Output Voltage | 208v, 220v, 480v, 600v Three Phase |
Output Voltage Reg | V +1% static |
Efficiency | 90% + |
Battery:
Runtime | Various, 10 min + |
General:
Power Rating | 250kVA, 300kVA, 400kVA, 500kVA, 625kVA, 750kVA, 800kVA, 1000kVA, 1100kVA |
Voltage | 208v, 220v, 480v, 600v Three Phase |
Frequency | 50/60Hz |
Product Series | Liebert / Vertiv NXL Model UPS |
Liebert NXL 250-800kVA UPS Brochure | Liebert-NXL-250-800kVA-UPS-Brochure.pdf |
Liebert NXL 250-1100kVA Operation and Maintenance Manual | Liebert-NXL-250-1100kVA-Operation-and-Maintenance-Manual.pdf |
Liebert NXL 250-400kVA UPS Installation Manual | Liebert-NXL-250-400kVA-UPS-Installation-Manual.pdf |